Long loop and short loop circulation on DHT

Home Forums Petro Solutions Forum Hydroprocessing Long loop and short loop circulation on DHT

Viewing 4 reply threads
  • Author
    Posts
    • #1440
      Abu noor
      Moderator

      What is the purpose of the cold, hot long loop circulation and short loop circulation on the hydrotreater unit?
      And we can use hot or cold long loop circulation?

    • #1443
      Nasir Hussain
      Keymaster

      There are two loops in the typical hydrotreating units;
      1. The short loop is from the downstream of the HP separator Hydrocarbon line towards the product stripper. Then the line up of stripper downstream to diesel product header or slop tank. This can also be sent to the feed storage tank. For flushing, straight-run cold diesel is used.
      The purpose of short loop circulation during commissioning is to clean, remove debris, checking leakages, etc and make ready the unit before commissioning. This can also be applied after turnaround or after any major overhauling of the stripper section.
      Secondly, circulation with cold diesel is applied for cool down and hand over stripper feed exchangers or any hot equipment for a maintenance job.
      2. Long loop circulation is through the complete unit. It is carried out after catalyst loading or Turnaround. Its purpose is to perform Pre-wetting the catalyst and remove catalyst dust and any other debris or loose materials from the reactor circuit and then passed through the fractionation section which has already been flushed.
      For ~4-6 hours, the circulation is once through then internal circulation is started. After that sulfiding of the hydrotreating catalyst is carried out.

      Sulfiding of Hydrotreating Catalysts and its Troubleshooting

    • #1449
      Abu noor
      Moderator

      Thanks Mr.Nasir
      Once flushing is completed through system we can stop Fractionator pump which is used for internal circulation?
      Only we will keep long loop circulation if not why?

    • #1451
      Nasir Hussain
      Keymaster

      Yes once the short loop circulation for 4-6 hours has been completed then it should be stopped.
      It will be difficult to continue both the circulations probably will not be possible.

    • #1454
      Abu noor
      Moderator

      Thanks Mr.Nasser
      For fast response

Viewing 4 reply threads
  • You must be logged in to reply to this topic.